. New Modules for Siprocess GA700 © Siemens
See also:
> EnergyPost
> Gas for Energy

 

 

Siemens: New modules for Siprocess GA700
enable comprehensive analytical solutions

• "Ultramat 7" and "Calomat 7" modules expand the analytical spectrum of Siprocess GA700
• Simple module installation and replacement using "Plug and Measure" principle
• Parameter assignment and diagnostics using Simatic PDM (Process Device Manager)
• Main field of application is process monitoring in chemical, petrochemical and incineration plants


April 20, 2015  + + +  With "Ultramat 7" and "Calomat 7", Siemens is offering two new analyzer modules for its Siprocess GA700 gas analysis system. Together with the "Oxymat 7" module which is already available, users can thus configure flexible analytical solutions, for example for measuring oxygen, hydrogen, noble gases or infrared-active components such as carbon monoxide and carbon dioxide. The modular design of the Siprocess GA700 enables fast module installation and replacement using the "Plug and Measure" principle. Depending on the configuration, the units can be used at temperatures up to 50 °C. They are particularly suitable for process control and optimization in incineration plants and for quality control and process monitoring in chemical and petrochemical plants.

With the launch of the Siprocess GA700 in 2012, Siemens introduced a new device concept for the extractive gas analysis. The device comprises a base unit (enclosure including operator interfaces and customer interfaces) into which one or two modules can be integrated. The modules, as the actual analyzer unit, provide the sensor-based electronics including evaluation software, as well as the process connections. The influence of interfering gases can then be measured and mutually offset. The modular design provides greater flexibility with regard to upgrading or retrofitting since modules are automatically recognized and configured. This approach also simplifies maintenance and repair measures.

In addition to the already available Oxymat 7 module for oxygen measurements, users can now use the Calomat 7 to carry out quantitative determinations of hydrogen and noble gases in binary or quasi-binary gas mixtures. Depending on the parameter settings, the measuring ranges for H2 are 0 to 0.5%, 0 to 100% or 95 to 100%. The module can therefore be used equally well both for pure gas monitoring and protective gas monitoring or for determining H2 in blast furnace or converter gases.

The Ultramat 7 module carries out highly selective measurements of up to two infrared-active components such as carbon monoxide and dioxide. The unit can be integrated, for example, in measuring equipment for boiler control in incineration plants. Furthermore, the module can be used to measure the concentrations of process gases in chemical plants.

Users can configure, parameterize and start up the Siprocess GA700 using the Simatic PDM (Process Device Manager). In addition, the software tool provides functions for diagnostics and maintenance of the gas analyzer. More: www.siemens.com/cga

Source: David Petry, Siemens AG,
Process Industries and Drives Division

www.siemens.com






 



Worldwide more than
100,000 paid subscriptions

 


Worldwide more than 48,000 subscriptions -
100% one-year direct request qualification

 


'What's New' in Upstream, Midstream and Downstream Products & Services. Circulation 37,000

 
PennWell
Petroleum Group:

Oil & Gas Journal
Oil & Gas Journal Russia
OGJ_eNewsletter
 
OGJ-Website-Statistics

Oil, Gas & Petrochem Equipment

Offshore Magazine
Offshore Russia
Offshore eNewsletter 
Offshore Website Statistics

Oil & Gas Financial Journal

+ + + 

 For more information, media kits or sample copies please contact
Andreas Sicking
+49 (0)2903-338570

wilhelms@pennwell.com www.sicking.de


Please send news releases to Wilhelm Sicking - sicking-media@email.de